*USER OUTPUT VARIABLES
Specify number of user variables.

This option is used to allow Abaqus to allocate space at each material calculation point for user-defined output variables defined in user subroutine UVARM. If the *USER OUTPUT VARIABLES option is used, it must appear within each of the relevant material or gasket behavior definitions.

Products: Abaqus/Standard  Abaqus/CAE  

Type: Model data

Level: Model  

Abaqus/CAE: Property module

Reference:
There are no parameters associated with this option.

Data line to specify the number of user variables: 

First (and only) line:

  1. Number of user-defined variables required at each material point.