This option is used to define the properties of a user element.
Products: Abaqus/Standard Abaqus/Explicit Abaqus/CAE
Type: Model data
Level: Part, Part instance, Model
Abaqus/CAE:
Set this parameter equal to the name of the element set containing the user elements for which these property values are being defined.
This parameter applies only to Abaqus/Standard analyses.
Set this parameter equal to the name of the material to be used with these elements.
This parameter applies only to Abaqus/Standard analyses.
Set this parameter equal to the name of an orientation definition (“Orientations,” Section 2.2.5 of the Abaqus Analysis User's Guide) to be used to define a local coordinate system for material calculations in the elements in this set.
Set this parameter equal to the Rayleigh mass damping factor, .
Set this parameter equal to the Rayleigh stiffness damping factor, .
First line:
Enter the values of the element properties. Enter all floating point values first, followed immediately by the integer values.
Repeat this data line as often as necessary. Eight values per line are used for both real and integer values.