*TENSILE FAILURE
Specify a tensile failure model and criterion.

This option is used with the Mises or the Johnson-Cook plasticity models or the equation of state model to specify a tensile failure model and criterion. It must be used in conjunction with the *PLASTIC, HARDENING=ISOTROPIC option; the *PLASTIC, HARDENING=JOHNSON COOK option; or the *EOS option.

Product: Abaqus/Explicit  

Type: Model data

Level: Model  

References:

Optional parameters:

DEPENDENCIES

Set this parameter equal to the number of field variable dependencies included in the definition of the hydrostatic cutoff stress, in addition to temperature. If this parameter is omitted, it is assumed that the hydrostatic cutoff stress is constant or depends only on temperature. See Using the DEPENDENCIES parameter to define field variable dependence in Material data definition, Section 21.1.2 of the Abaqus Analysis User's Guide, for more information.

ELEMENT DELETION

Set ELEMENT DELETION=YES (default) to allow element deletion when the failure criterion is met.

Set ELEMENT DELETION=NO to allow BRITTLE/DUCTILE-type failure for the deviatoric and hydrostatic parts of stresses.

Required parameters for use with ELEMENT DELETION=NO

PRESSURE

Set PRESSURE=BRITTLE to model the case where the pressure stress is required to be compressive when the failure criterion is met.

Set PRESSURE=DUCTILE to model the case where the pressure stress will be limited by the hydrostatic cutoff stress when the failure criterion is met.

SHEAR

Set SHEAR=BRITTLE to model the case where the deviatoric stresses will be set to zero when the failure criterion is met.

Set SHEAR=DUCTILE to model the case where the deviatoric stresses will be unaffected when the failure criterion is met.

Data lines to specify a tensile failure model: 

First line:

  1. Hydrostatic cutoff stress (positive in tension). (Units of FL–2.)

  2. Temperature.

  3. First field variable.

  4. Second field variable.

  5. Etc., up to six field variables.

Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than six):

  1. Seventh field variable.

  2. Etc., up to eight field variables per line.

Repeat this set of data lines as often as necessary to define the dependence of hydrostatic cutoff stress as a function of temperature and other predefined field variables.