This option is used to specify a material's specific heat.
Products: Abaqus/Standard Abaqus/Explicit Abaqus/CFD Abaqus/CAE
Type: Model data
Level: Model
Abaqus/CAE: Property module
This parameter applies only to Abaqus/Standard and Abaqus/Explicit analyses.
Set this parameter equal to the number of field variables included in the definition of specific heat. If this parameter is omitted, it is assumed that the specific heat is constant or depends only on temperature. See “Specifying field variable dependence” in “Material data definition,” Section 21.1.2 of the Abaqus Analysis User's Guide, for more information.
This parameter applies only to Abaqus/Standard analyses.
Include this parameter if the specific heat of the pore fluid in a porous medium is being defined.
This parameter applies only to Abaqus/CFD analyses.
Set TYPE=CONSTANT VOLUME (default) to define the specific heat at constant volume.
Set TYPE=CONSTANT PRESSURE to define the specific heat at constant pressure when the energy equation is used for thermal-flow problems.
First line:
Specific heat per unit mass. (Units of JM–1–1.)
Temperature.
First field variable.
Second field variable.
Etc., up to six field variables.
Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than six):
Seventh field variable.
Etc., up to eight field variables per line.
Repeat this set of data lines as often as necessary to define the specific heat as a function of temperature and other predefined field variables.