This option is used to set the control parameters for both the direct and iterative linear equation solvers.
Products: Abaqus/Standard Abaqus/CAE
Type: History data
Level: Step
Abaqus/CAE: Step module
Include this parameter to optimize the handling of hard contact and compressibility constraints associated with hybrid elements.
Include this parameter to reset all of the iterative solver controls to their default values. The option should have no data lines when this parameter is used.
If this parameter is omitted, only the iterative solver specified controls will be changed in the current step; the other controls will remain at their settings from previous steps.
First (and only) line:
Relative tolerance for convergence. The default is 10–3 for all general procedures. For linear perturbation procedures, the default is 10–6.
Maximum number of iterations allowed. The default is 300.
ILU factorization fill-in level. The default is 0; the maximum is 3. This parameter applies only to porous media (soils) analyses.