This option is used to write cavity radiation variables to the Abaqus/Standard results file.
Products: Abaqus/Standard Abaqus/CAE
Type: History data
Level: Step
Abaqus/CAE:
Set this parameter equal to the name of the cavity for which this output request is being made.
Set this parameter equal to the name of the element set for which this output request is being made.
Set this parameter equal to the name of the surface for which this output request is being made.
Set this parameter equal to the output frequency, in increments. The output will always be written to the results file at the last increment of each step unless FREQUENCY=0. The default is FREQUENCY=1. Set FREQUENCY=0 to suppress the output.
First line:
Give the identifying keys for the variables to be written to the results file for this request. The keys are defined in the “Surface variables” section of “Abaqus/Standard output variable identifiers,” Section 4.2.1 of the Abaqus Analysis User's Guide.
Repeat this data line as often as necessary to define the surface variables to be written to the results file for the specified cavity, surface, or element set. If this line is omitted, the default variables will be used.