This option is used to define particle flow speed and particle species mass flow rate per unit inlet area.
Product: Abaqus/Explicit
Type: History data
Level: Part, Part instance
Set this parameter equal to the name of the particle generator for which the flow speed and mass flow rate per unit inlet area are being specified.
First line:
Enter a single amplitude name for the particle flow speed at the generator inlet.
Enter the list of amplitude names for the mass flow rate per unit inlet area for each species for the particle generator mixture. The order is consistent with the species specified on the *PARTICLE GENERATOR MIXTURE option.
Repeat this data line as often as necessary to add more mass flow rates per unit inlet area amplitude names. Up to 16 entries are allowed per line.