This option is used to specify a change in the amount of fluid in a fluid-filled cavity modeled with hydrostatic fluid elements.
Products: Abaqus/Standard Abaqus/Explicit
Type: History data
Level: Step
Set this parameter equal to the name of the amplitude versus time curve that defines the magnitude of the mass flow rate during the step (“Amplitude curves,” Section 34.1.2 of the Abaqus Analysis User's Guide). If this parameter is omitted, the reference magnitude is applied immediately at the beginning of the step, regardless of the procedure being used in the step.
Set OP=MOD (default) for existing fluid fluxes to remain, with this option defining fluid fluxes to be added (to cavities with no fluid flux loading) or modified (to cavities with fluid flux loading).
Set OP=NEW if all existing fluid fluxes applied to the model should be removed.
First (and only) line:
Node number or node set label of the cavity reference node.
Reference magnitude of the fluid mass flow rate, q. (Units of MT–1.)