This option is used to define linear multi-point constraints in the form of an equation.
Products: Abaqus/Standard Abaqus/Explicit Abaqus/CAE
Type: Model data
Level: Part, Part instance, Assembly
Abaqus/CAE: Interaction module
Set this parameter equal to the name of the alternate input file containing the data lines for this option. See “Input syntax rules,” Section 1.2.1 of the Abaqus Analysis User's Guide, for the syntax of such file names. If this parameter is omitted, it is assumed that the data follow the keyword line.
First line:
Number of terms, N, in the equation.
Second line:
Node number or node set label, P, of first nodal variable, .
Degree of freedom, i, at above node for variable .
Value of .
Node number or node set label, Q, of second nodal variable, .
Degree of freedom, j, at above node for variable .
Value of .
Etc., up to four terms per line.
Repeat the second data line as often as necessary to define all of the terms of the equation. No more than four terms can be defined on a line. To define another constraint, repeat the entire set of data lines.