This option is used to write a summary of the total energy content of a model to the results (.fil) file in an Abaqus/Standard analysis or to the selected results (.sel) file in an Abaqus/Explicit analysis. In an Abaqus/Explicit analysis it must be used in conjunction with the *FILE OUTPUT option.
Products: Abaqus/Standard Abaqus/Explicit Abaqus/CAE
Type: History data
Level: Step
Abaqus/CAE:
This parameter applies only to Abaqus/Standard analyses.
Set this parameter equal to the name of the element set for which this output request is being made. If this parameter is omitted, the energy for the whole model will be output.
This parameter applies only to Abaqus/Standard analyses.
Set this parameter equal to the output frequency, in increments. The output will always be written to the results file at the last increment of each step unless FREQUENCY=0. The default is FREQUENCY=1. Set FREQUENCY=0 to suppress the output.