*EMISSIVITY
Specify surface emissivity.

This option is used to define the emissivity of a surface in a cavity radiation problem. It must appear immediately after the *SURFACE PROPERTY option and must be used in conjunction with the *PHYSICAL CONSTANTS option, which is used to define the Stefan-Boltzmann constant.

Products: Abaqus/Standard  Abaqus/CAE  

Type: Model data

Level: Model  

Abaqus/CAE: Interaction module

References:

Optional parameter:

DEPENDENCIES

Set this parameter equal to the number of field variables included in the definition of emissivity. If this parameter is omitted, the emissivity is assumed not to depend on any field variables (but may still depend on temperature). See Specifying field variable dependence” in “Material data definition, Section 21.1.2 of the Abaqus Analysis User's Guide, for more information.

Data lines to define the emissivity of a surface: 

First line:

  1. Emissivity, .

  2. Temperature, if temperature dependent.

  3. First field variable.

  4. Second field variable.

  5. Etc., up to six field variables.

Subsequent lines (only needed if the DEPENDENCIES parameter has a value greater than six):

  1. Seventh field variable.

  2. Etc., up to eight field variables per line.

Repeat this set of data lines as often as necessary to define the emissivity as a function of temperature and user-defined field variables.