This option is used to provide tabular printed output of contact variables for contact surface pairs.
Product: Abaqus/Standard
Type: History data
Level: Step
Set this parameter equal to the output frequency, in increments. The output will always be printed at the last increment of each step unless FREQUENCY=0. The default is FREQUENCY=1. Set FREQUENCY=0 to suppress the output.
Set this parameter equal to the name of the master surface for which this output request is being made.
Set this parameter equal to the name of the node set for which this output request is being made.
Set this parameter equal to the name of the slave surface for which this output request is being made.
Set SUMMARY=YES (default) to obtain a summary of the maximum and minimum values in each column of the table and their locations. Set SUMMARY=NO to suppress this summary.
Set TOTALS=YES to print the total of each column in the table. The default is TOTALS=NO.
First line:
Give the identifying keys for the variables to be written to the data file for this contact pair. The keys are defined in “Abaqus/Standard output variable identifiers,” Section 4.2.1 of the Abaqus Analysis User's Guide.
Repeat this data line as often as necessary: each line defines a table. If this line is omitted, the default variables will be output.