This option is used to prescribe time-dependent allowable interferences for contact pairs and contact elements. It is useful for solving problems where there are large initial overclosures of the contacting bodies.
Products: Abaqus/Standard Abaqus/CAE
Type: History data
Level: Step
Abaqus/CAE: Interaction module
Set this parameter equal to the name of the amplitude curve that defines the magnitude of the prescribed interference during the step. If this parameter is omitted, the prescribed interference is applied immediately at the beginning of the step and ramped down to zero linearly over the step.
Set OP=MOD (default) for existing *CONTACT INTERFERENCE definitions to remain, with this option defining a contact interference to be added or modified. Set OP=NEW if all *CONTACT INTERFERENCE definitions defined in previous steps should be removed.
Include this parameter to invoke the automatic shrink fit capability. This capability can be used only in the first step of an analysis. When this parameter is included, no data are required other than the contact pairs or elements to which the option is applied. In addition, any AMPLITUDE reference specified will be ignored.
Use this parameter to specify whether the prescribed interference will be applied to contact pairs or contact elements. Set TYPE=CONTACT PAIR (default) to specify a contact interference for contact pairs. Set TYPE=ELEMENT to specify a contact interference for contact elements.
First line:
Slave surface name.
Master surface name. It must be distinct from the slave surface name; self-contact is not allowed with this option.
If the SHRINK parameter is included, no additional data are required. Otherwise:
Reference allowable interference, v.
X-direction cosine of the shift direction vector (optional).
Y-direction cosine of the shift direction vector (optional).
Z-direction cosine of the shift direction vector (optional).
Repeat this data line as often as necessary to specify additional contact pairs. Each line defines a distinct contact interference between one contact pair.
First line:
Name of the element set containing the contact elements.
If the SHRINK parameter is included, no additional data are required. Otherwise:
Reference allowable interference, v.
X-direction cosine of the shift direction vector (optional).
Y-direction cosine of the shift direction vector (optional).
Z-direction cosine of the shift direction vector (optional).
Repeat this data line as often as necessary to specify additional element sets containing contact elements.