This option can be used only in conjunction with the *VISCOELASTIC option and cannot be used if the *SHEAR TEST DATA and *VOLUMETRIC TEST DATA options are used.
Products: Abaqus/Standard Abaqus/Explicit Abaqus/CAE
Type: Model data
Level: Model
Abaqus/CAE: Property module
To specify creep test data, set this parameter equal to the value of the long-term, normalized shear compliance .
To specify relaxation test data, set this parameter equal to the value of the long-term, normalized shear modulus .
The shear compliance and shear modulus are related by . The fitting procedure will use the specified value in the constraint .
To specify creep test data, set this parameter equal to the value of the long-term, normalized volumetric compliance .
To specify relaxation test data, set this parameter equal to the value of the long-term normalized volumetric modulus . The volumetric compliance and volumetric modulus are related by . The fitting procedure will use this value in the constraint .